If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
page date 1 of 5 11/19/2007 PART NUMBER: VPF-S200-XXRI series DESCRIPTION: switching power supply features *power factor correction *power good signal *short circuit protection *over load, voltage, temperature protection *approved to UL/cUL, TUV, CE with CB scheme *N+1 parallel redundancy *extended temperature range: -40 ~ +75C available MODEL VPF-S200-03RI VPF-S200-05RI VPF-S200-12RI VPF-S200-24RI VPF-S200-36RI VPF-S200-48RI notes: output 1, 2, 3 (V) preset voltage (V) max. output 4 power / current (A) with force air convection regulation 5 ripple & noise 5, 6 (Vp-p) 3 5 12 24 32 48 - 4V 6V 18 V 30 V 46 V 56 V 3.3 V 5V 12 V 24V 36 V 48 V 30 A 200W 200W 200W 200W 200W 22 A 22 A 150W 150W 150W 150W 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1. customer must specify output voltage on PO 2. output is fully isolated 3. output voltage is measured at output power connector 4. maximum 200 W with 18. cfm forced ventilation 5. 1% minimum load is required to maintain the ripple and regulation 6. ripple and noise are measured from 10 KHz to 20 MHz at output terminals with a 0.1 F ceramic capacitor and a 22 F capacitor in parallel. 20050 SW 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 fax 503.612.2382 page date 2 of 5 11/19/2007 PART NUMBER: VPF-S200-XXRI series DESCRIPTION: switching power supply INPUT parameter input frequency input voltage input current inrush current power factor conditions/description 90~132 / 180~264 auto-selectable AC input of 115 VAC AC input of 230 VAC peak measured at 115 VAC at full load, cold start min 47 90 nom max 63 264 5 2.5 35 units Hz VAC A A A peak measured at 230 VACat full load, cold start 70 A active power factor correction meets EN61000-3-2 class A (total output power not to exceed 200 W) OUTPUT parameter transient response overshoot efficiency conditions/description output voltage returns to within 1% in less than 2.5ms for a 50% load change. peak transient does not exceed 5%. turn-on and turn-off overshoot will not exceed 5% over nominal voltage measured at 230 V and full load: 3.3 V model 5 V model 12 V model all other models at 120 V ac, full load at 120 V ac, full load output use adjustable when green (LED1) is on, power supply is operating normally designated as PG on the CN1. this signal goes high 100-500 mS after the output reaches regulation. low at least 1 mS before loss of regulation. min nom max units 70 75 80 83 1 20 +5 % % % % S mS % start up time hold up time adjustability LED display power good -5 PROTECTION CIRCUITS parameter input fuse overload output over-voltage short circuit over temp. conditions/description one T5A / 250V fuse inserted in primary current limiting starts at 110~135% of the rated output current in foldback mode and recovers automatically output is protected against overvoltage. Unit shuts down and latches when voltage at output terminals exceeds 130%. ac input needs to be reset to restart the power supply. trip without damage and auto-recovery. Power supply shuts down when temperature is in excess of 85 C. auto recovery. 20050 SW 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 fax 503.612.2382 page date 3 of 5 11/19/2007 PART NUMBER: VPF-S200-XXRI series DESCRIPTION: switching power supply GENERAL & SAFETY parameter operating temp. optional operating temp. storage temp. optional storage temp. operating humid. storage humid. operating altitude storage altitude EMI safety conditions/description derates linearly from 100% load at 50C to 50% load at 70C derates linearly from 100% load at 50C to 37.5% load at 75C min 0 -40 -20 -40 5% 5% nom max 40 75 85 85 90% 95% 3,000 10,000 9,000 30,000 units C C C C RH RH m ft m ft non-condensing non-condensing conducted emissions comply with FCC part 15, CISPR 22 class B approved to UL 1950(E222889), CSA C22.2 No. 60950-1-03, TUV EN60950-1, CE Mark (LVD), EN61000-3-2, & IEC61000-4 series regulations, CB leakage current at 240 V ac 1.5 mA vibration acceleration 7.35 M/(SxS), on X, Y, and Z axis 5 50 Hz isolation voltage applied for 3 seconds. (HI-POT) primary to secondary: 3000 VAC primary to transformer core: 1500 VAC primary to earth ground: 1500 VAC grounding test allowable resistance measured when 25 A current is 0.1 applied from the ground pin of the three pronged plug to the farthest earthed connection point. RoHS yes warranty standard warranty length 2 years MTBF according to MIL-HDBK-217 at 30C 100,000 hours burn-in full load, at 45 5C, 230 V ac 1 hours cooling built-in dc fan speed control Note: Customer must specify extended temperature on PO. MECHANICAL parameter dimensions weight mountin screws conditions/description 6.8"(172.7mm) x 3.8"(96.5mm) x 1.5"(38.1mm) U-case min nom max 600 one set of 8 threaded mounting holes available on the enclosure A:M4, maximum insertion depth of 0.2 inches. units g MATING CONNECTORS parameter AC input(option 1) conditions/description Molex Part No. 26-48-1201 or similar (5 pin). Suggested mating plug: Molex Part No. 09-91-0500 or equivalent (5 pin, 3 used) AC input(option 2) Terminal block Part No. FTB-702-3P (3 pin, M3 Screw) 7.62mm spacing Suggested mating connector: Molex 19198-0016 or similar Note: Input connector must be specified on PO. 20050 SW 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 fax 503.612.2382 page date 4 of 5 11/19/2007 PART NUMBER: VPF-S200-XXRI series DESCRIPTION: switching power supply OUTPUT CONNECTOR - (CN2) parameter output (option 1) conditions/description min nom Molex Part No. 09-91-1200 or similar. (12 pin) Output pin assignment, VO+ (Pins 1-6), VO- (Pins 7-12) Suggested mating connector: Molex 12 pin (part No. 09-91-1200) Howder Terminal block Part No. HD-301-4P (4 pin, M3.5 Screw) 11mm spacing Output pin assignment, VO+ (Pins 1-2), VO- (Pins 3-4) Suggested mating connector: Molex 19198-0045 or similar. max units output (option 2) Note: Output connector must be specified on PO. LOGIC CONNECTOR - (CN3) parameter Logic Pin Assignments: conditions/description min nom max JS B6B-XH-A Suggested mating connector: JS-2001-06 or equivalent , Contact: SXH-002T-P0.6. 1. FAN+ 2. FAN3. RTN 4. PG 5. REMO 6. RTN units 20050 SW 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 fax 503.612.2382 page date 5 of 5 11/19/2007 PART NUMBER: VPF-S200-XXRI series DESCRIPTION: switching power supply OUTLINE DRAWING OUTPUT VO- 20050 SW 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 fax 503.612.2382 INPUT VO- VO+ VO+ |
Price & Availability of VPF-S200-48RI |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |